7ab0ce6501
Because the registration RPC was not really an RPC, but a bunch of disconnected messages, it was possible for other messages to be sent before the reply to the registration arrived, and that would confuse the Worker. Especially in local-cluster mode, the worker was succeptible to receiving an executor request before it received a message from the master saying registration succeeded. On top of the above, the change also fixes a ClassCastException when the registration fails, which also affects the executor registration protocol. Because the `ask` is issued with a specific return type, if the error message (of a different type) was returned instead, the code would just die with an exception. This is fixed by having a common base trait for these reply messages. Author: Marcelo Vanzin <vanzin@cloudera.com> Closes #9138 from vanzin/SPARK-11131. |
||
---|---|---|
.. | ||
main | ||